AI video analytics for Reference Condition Monitoring
Reference condition monitoring with AI video analytics checks whether a visible condition corresponds to a defined reference image or specified inspection criteria. The system detects relevant deviations and provides them in a structured manner for further processing.
Direct answer
What is reference condition monitoring?
AI-based reference condition monitoring compares a current camera view or image with a defined reference condition. Reference images, fixed rules or a functional description can define that condition.The system detects relevant deviations and documents them with camera, time and image context. This makes it possible to automate visual checks that would otherwise have to be carried out manually on a regular basis.
Reference Condition Monitoring
The analysis checks whether a visible situation meets a defined target condition or defined visual test criteria.
- ResultThe system recognises relevant target-actual deviations and provides them with visual evidence, time and test result.
- ResultsContinuous video analytics – Job and VLM processing
- PlatformsSynaEYE, SynaHUB
- QualityWe validate the analysis with real positive, negative and border cases under the actual operating conditions.
Scope of detection
Reference Condition Monitoring: capabilities and results.
The analytics evaluates more than individual objects. It checks whether the entire visible situation meets the defined requirements. Depending on the application, object classes, positions, zones, reference images or written criteria can describe the reference condition.
From image to process
Reference Condition Monitoring in operational workflows.
The platform turns a functionally defined reference condition into a repeatable visual inspection. Detected deviations can be documented, prioritised or passed directly to downstream processes.

Defining test criteria
We determine which objects, positions, states or visual criteria must be met.

Analyse
SynaEYE or SynaHUB analyses the relevant camera scene or shot and compares it with the defined requirements.

Structure result
The system returns a structured result, such as criteria met or not met, object present or absent, or a defined deviation.

Integrate
The platform passes test results to dashboard, quality system, operation application, workflow or via REST API to third-party systems.
Typical applications
Where is reference condition monitoring used?
Reference condition monitoring is suitable for processes in which a visible reference condition must be checked regularly or in response to an event.
Quality testing
In production and production, the analysis can check whether products, components or work areas meet the specified visual requirements.
Workplace and plant condition
Workplaces, machinery areas and technical plants can be checked for defined conditions. For example, the system can detect whether required components are present, objects have been positioned correctly or an area is prepared according to the regulations.
Logistics and Completeness
Storage locations, picking areas and transfer zones can be checked for completeness, occupancy and defined reference conditions.
Building and security areas
Escape routes, technical rooms, security areas or other building areas can be regularly controlled for defined states.
Job-related visual control
SynaHUB can check individual images or defined image inventories based on the job. This allows recurring visual inspections to be automated without having to permanently analyse any area as a video stream.
Suitable platforms
Which platform supports reference condition monitoring?
The right platform depends on your task: evaluating ongoing camera images, checking individual states according to a schedule or centrally operating several analyses.

Operational video analytics
Continuous AI video analytics for live camera streams
SynaEYE continuously analyses existing cameras in real time and combines detection, event logic, alerts, tracking and forensics in a European edge AI platform.
The right choice if you:want to monitor security, safety or operational processes continuously with your cameras and process detected events immediately.

Periodic image checks
Check the reference condition regularly
SynaHUB combines a camera image with a clear test question and, if necessary, a reference image. According to your schedule, the platform checks visible deviations and provides results in a comprehensible manner.
The right choice if you:Completeness, positions or other visible states in recurring controls.
Inspection intervals, reference images and image quality depend on your task. The result describes the visible state of the tested image.
Compare platformsResponsibility and feasibility
Reference Condition Monitoring: limitations and requirements.
Reference condition monitoring can evaluate visible features only. Camera perspective, resolution, lighting, occlusions and permitted variants therefore affect inspection quality. We test relevant situations with representative footage before production deployment.
Reference condition and tolerances
The reference condition must have a clear functional definition. Permitted variants and tolerances must be considered during configuration.Visibility
The system can only check features that are sufficiently visible in the camera image. Concealed components or technically invisible states cannot be reliably evaluated using the camera image alone.Environmental influences
Changes in light, shadows, object positions or the surrounding environment can alter a scene even when the required reference condition is still met.Professional context
The analysis detects visible deviations from defined test criteria. It cannot automatically derive from this whether a system is technically functional or a process is technically completed correctly if this information is not recognizable in the image. In the case of critical quality, security or process decisions, additional data sources or human review should be included.Assess data protection requirements for your specific use case. For EU locations, refer to the GDPR and the EDPB guidelines on video surveillance. Also consider the requirements of the EU AI Act, where applicable to your use case.
For private operators in Switzerland, the FDPIC guidance on video surveillance guidance.
Frequently asked questions
Target-to-actual inspection explained in brief.
What is reference condition monitoring?
AI-based reference condition monitoring compares a current camera view or image with a defined reference condition. Reference images, fixed rules or a functional description can define that condition.The system detects relevant deviations and documents them with camera, time and image context. This makes it possible to automate visual checks that would otherwise have to be carried out manually on a regular basis.
What does reference condition monitoring detect?
Configurable inspection criteria are: target-actual deviation, completeness, position and condition, textually described test criteria. We validate which of these work reliably using real scenes.
Where is reference condition monitoring used?
Typical applications include quality inspection, workplace and plant condition, logistics and completeness, building and security areas, job-related visual inspection. A defined follow-up process is decisive.
Which platform supports reference condition monitoring?
SynaEYE, SynaHUB are eligible depending on the task. SynaHUB combines a camera image with a clear test question and, if necessary, a reference image. After your schedule, the platform checks visible deviations and provides results in a comprehensible manner. Test intervals, reference pictures and image quality depend on your task. The result describes the visible state of the tested recording.
What are the limitations of reference condition monitoring?
The reference condition must have a clear functional definition, including permitted variants and tolerances. The system can assess only features that are sufficiently visible in the camera image; concealed components or technical conditions outside the image cannot be evaluated reliably. Changes in light, shadows, object positions or the surrounding environment can alter a scene even when the required condition is still met. The analytics identifies visible deviations from defined inspection criteria, but it cannot infer technical functionality or process completion when that information is not visible. Critical quality, safety or process decisions should therefore include additional data sources or human review.
Does the analytics work with existing cameras?
In many cases, yes. The decisive factors are perspective, resolution, lighting, frame rate, compression and the visible size of the relevant feature.
Validate before scaling
Test reference condition monitoring with your cameras.
We assess the scene, image quality, data protection, integrations and response process using real data.
Discuss your use case




